LC2010 semi-preparative liquid chromatography

Solvent Delivery: Dual-plunger reciprocating pump with dual-plunger aspiration for minimal pulsation; electronic compensation for precise flow rates.
The LC2010 Semi-Preparative Gradient System is designed for laboratory purification requiring gradient elution conditions at flow rates up to 50 mL/min. Its flow range is suitable for columns with an inner diameter of 10 to 30 mm, meeting the needs of single-pass purification of milligram to gram quantities of samples, achieving optimal purity and recovery. It is primarily used for preparative separation and purification of samples requiring gradient elution conditions.

Product Details

The LC2010 Semi-Preparative Gradient System is designed for laboratory purification using gradient elution conditions at flow rates of 50 mL/min. Its flow range is suitable for columns with an inner diameter of 10 to 30 mm, meeting the needs of single-pass purification of milligram- to gram-scale samples, achieving optimal purity and recovery. It is primarily used for preparative separation and purification of samples requiring gradient elution conditions.
The LC2010 Semi-Preparative Isocratic System is also used for preparative method validation and optimization. Preparative chromatographic conditions derived from analytical HPLC can be scaled up to a semi-preparative system for verification and further optimization of recommended systems.

▮  Features and Features of the LC2010 Semi-Preparative
◾ Solvent Delivery: Dual-plunger reciprocating pump, dual-plunger aspiration, minimal pulsation; electronic compensation, precise flow rate;
◾ Fast start and stop, adjustable maximum/minimum pressure, automatic storage of user data;
◾ High-pressure protection: automatic shutdown when pressure exceeds the set value;
◾ Dynamic mixing: more complete solvent mixing;
◾ Signal Detection: 190-700nm wavelength detection range, extending application range;
◾ Control Mode: Standalone control mode: All operating parameters can be set via touchscreen control for more flexible operation;
◾ Computer control mode: Control system via LAN connection using chromatography workstation software;
◾ Mainly used for separation and purification of target monomers from mixtures. Compatible with both normal and reversed-phase solvent systems

Optional: Available in standard and biocompatible versions

Instrument status (running, error, sleep) can be viewed via the panel indicator

Gradient error limit: ±1%

Gradient repeatability deviation limit: <1%

Specifications: LC2010 Semi-Preparative

Used primarily for R&D applications in pharmaceuticals, food sciences, chemical engineering, life sciences, universities, and research institutes;
For example: high-throughput screening of active substances for drug discovery and development, and laboratory-scale purification (gram-scale).